成人亚洲精品777777-成人亚洲精品久久久久-成人亚洲精品久久久久软件-成人亚洲区无码区在线点播-成人亚洲性情网站www在线观看-成人艳情一二三区

Products

current position:home page>Products>Analysis Instrument>PST>

Oxygen Analyzer - Michell XTP601

Updated:2025-03-13

Views:158

  • Brand: PST/Michell
  • Model: XTP601
  • Description: The XTP601 Oxygen Analyzer for safe or hazardous areas is a robust, linear and stable device that is used for measurements in gases such as biogas, methane, hydrogen, nitrogen or carbon dioxide. The a
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Oxygen Analyzer - Michell XTP601 Description:

User’s Manual Datasheet Order Selection Table

Low-maintenance O2 Measurement

Features

General purpose or ATEX, UKCA, IECEx, cQPSus, TR CU & Ex hazardous area certified models

SIL2 Capable

Ranges available: 0...0.5 % up to 0...50 % & 20, 80 or 90...100 %

Touch-screen display allows calibration or adjustment without the need for a hot works permit

Intrinsic error (accuracy) is better than 1 % full scale

Zero range stability better than 0.25 % of range per month

Outputs include RS485 and two 4...20 mA (following NAMUR NE 44 standard)

Low cost of ownership due to minimal maintenance and no consumable parts

The XTP601 Oxygen Analyzer for safe or hazardous areas is a robust, linear and stable device that is used for measurements in gases such as biogas, methane, hydrogen, nitrogen or carbon dioxide. The analyzer is SIL2 Capable.

A robust, linear and stable oxygen analyzer for measurements in gases such as hydrogen, nitrogen, methane, biogas, or carbon dioxide. The analyzer is housed in an IP66 rugged casing, making it suitable for a wide range of applications. The XTP601 can be supplied with flame arrestors, as either explosion-proof and certified for use in hazardous areas or for use with flammable gases in a safe area.

Specifications

Performance
Measurement Technology Thermo-paramagnetic oxygen sensor
Gas Process and non-condensing sample with particles <5μm
Measurement Range Selectable from 0 to 0.5 % up to 0...50 % and 20, 80 or 90...100 %
Display Resolution 0.01 % for zero based ranges
0.1 % for supressed zero ranges
Display Type Backlit LCD
Accuracy Excluding Suppressed Zero Ranges ±0.02 % O2 or <±1 % of range, whichever is greater
Accuracy For Suppressed Zero Ranges (80/90...100 %) ±0.2 % O2 or <±1 % of range, whichever is greater
Response Time (T90) with High Speed Response (HSR) Enabled < 15 seconds
Repeatability ±0.2 % of range or 0.01 % O2, whichever is greater
Linearity ±0.5 % of range or 0.05 % O2, whichever is greater
Zero Stability ±0.25 % of range per month
Range Stability ±0.25 % of range per month
Sample Flow Rate 100...600 ml/min
Sample Flow Effect GP1 and GP3: 100...500 ml/min (0.2...1.06 scfh)
EX1, EX3 and GP2: 270...330 ml/min (0.2...1.06 scfh)
Sample Pressure 0.75...2 BarA
Sample Temperature A constant temperature of +5...+45/+55 °C
(+41...+113/+131 °F)
Sample Cell Temperature +50/+60 °C (+122/+140 °F)
Background Gas Analyzer is calibrated in the background gas of the process. Standard gases are: N2, CO2, CH4, H2 & Biogas. Others available on request
Electrical Specifications
Analog Inputs 2 off 4...20 mA inputs
One for an external sensor that can be displayed on the screen
One to act as an active compensation for the process conditions
Analog Outputs 2 off 4...20 mA outputs (powered with 24V excitation voltage)
Output Ranges Primary range is set to the calibrated range of the instrument
The second is user configurable between 0 and 100 %
Alarms 2 off single pole changeover (SPCO) relays for O2 concentration (250 V, 5 A max)
Datalogging The user can use the digital communications to log the output from the analyzer
The unit will store 40 alarm points and the min/max O2 concentrations with date and time stamp
Digital Communications Modbus RTU over RS485
Power Supply 24 V DC; 1.6 A max
Cable entries Analyzer is supplied with 3 x M20 cable entries. Cable glands, conduit entries and blanking plugs are available as accessories
Operating Conditions
Ambient Temperature +5...+60 °C (+41 °F...+140 °F)
+5...+50 °C (+41...+122 °F) cQPSus
Atmopheric pressure 750 mbar...1250 mbar
Mechanical Specifications
Warm Up Time <25 minutes
Stabilization Time 5 minutes
Dimensions 234 x 234 x 172 mm (w x d x h)
Weight 9.7 kg
Wetted Materials 316 & 430F stainless steel, borosilicate glass, platinum, 3M 2216, plus O-ring
O-Ring Materials Viton, Silicone or Ekraz
Gas Connection EX1, EX3 & GP2: 1/8” NPT (female)
GP1 and GP3: 1/4” NPT (female)
Ingress Protection IP66, NEMA 4X
Hazardous Area Classification
ATEX/UKCA II 2 G D Ex db IIB+H2 T6 Gb
Ex tb IIIC T85 °C Db IP66
IECEx Ex db IIB+H2 T6 Gb
Ex tb IIIC T85 °C Db IP66
cQPSus Class I, Division 1, Groups B,C,D, T6
Class I, Zone 1
AEx db IIB+H2 T6 Gb / Ex db IIB+H2 T6 Gb
TR CU 1 Ex d IIB+H2 T6 Gb
Temperature Ranges for ATEX/UKCA and IECEx
as per O-ring Type
Silicon: Ta = -40 °C...+60 °C (+50 °C for N. America, +55 °C for TR CU Ex (EAC)).
Viton®: Ta = -15 °C...+60 °C (+50 °C for N. America, +55 °C for TR CU Ex (EAC))
Ekraz: Ta = -10 °C...+60 °C (+50 °C for N. America, +55 °C for TR CU Ex (EAC))

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 色噜噜狠狠在爱丁香 | 亚洲一区二区精品视频 | 91精品国产综合久久香蕉922 | 久久草视频 | 69xx免费观看视频 | 亚洲在线精品 | 黄网站免费在线观看 | 韩日一区二区三区 | 四虎一区 | 亚洲a网| 九九黄色网 | 欧美大片a一级毛片视频 | 嫩草影院播放地址一二三 | 成人影院在线观看 | 成人毛片100部 | 国产午夜精品不卡观看 | 日韩精品网站 | 亚洲综合在线视频 | 久久精品视香蕉蕉er大臿蕉 | 毛片网战| 99热久久久久久久免费观看 | 九九热免费视频 | 亚洲午夜一区二区三区 | 亚洲天堂一区二区 | 最近国产中文字幕 | 久久国产精品免费观看 | 中文字幕在线三区 | 亚洲a网| 亚洲综合欧美综合 | 国产理论精品 | 99精品国产高清一区二区麻豆 | 国产成人精品一区二区三区四区 | 欧美黑人xxxx性高清版 | 国产精品三级久久久久久电影 | 国产精品一区二区精品 | 亚洲午夜视频 | 国产日韩在线观看视频 | 久久婷婷久久一区二区三区 | 国产成人91一区二区三区 | jizz黑丝| a网站在线观看免费网站 |