  • Brand: Hukseflux
  • Model: FHF04SC
  • Description: FHF04SC is a sensor for general-purpose heat flux measurement, combined with a heater. It is used when the highest level of quality assurance is required and for long-term heat flux measurement. It is
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

FHF04SC heat flux sensor Description:

User's Manual

FHF04SC is a sensor for general-purpose heat flux measurement, combined with a heater. It is used when the highest level of quality assurance is required and for long-term heat flux measurement. It is thin, flexible and versatile. FHF04SC measures heat flux through the object in which it is incorporated or on which it is mounted, in W/m2. The sensor in FHF04SC is a thermopile. This thermopile measures the temperature difference across FHF04SC’s flexible body. A type T thermocouple is integrated as well. The thermopile and thermocouple are passive sensors; they do not require power.

Multiple small thermal spreaders, which form a conductive layer covering the sensor, help reduce the thermal conductivity dependence of the measurement. With its incorporated spreaders, the sensitivity of FHF04SC is independent of its environment. Many competing sensors do not have thermal spreaders. The passive guard area around the sensor reduces edge effects and is also used for mounting.

Using FHF04SC is easy. It can be connected directly to commonly used data logging systems. The heat flux in W/m2 is calculated by dividing the FHF04SC output, a small voltage, by the sensitivity. The sensitivity is provided with FHF04SC on its product certificate. When used under conditions that differ from the calibration reference conditions, the FHF04SC sensitivity to heat flux may be different than stated on its certificate. See the user manual for suggested solutions.

Measuring heat flux, users may wish to regularly check their sensor performance. During use, the film heater is activated to perform a self-test. The heat flux sensor response to the self-test results in a verification of sensor performance. Implicitly also cable connection, data acquisition, thermal connection of sensor to its environment and data processing are tested. Heat flux sensors are often kept installed for as long as possible. Using self-testing, the user no longer needs to take sensors to the laboratory to verify their stable performance. In a laboratory environment, using a metal heat sink, you may even perform a formal calibration. The heater has a well characterised and traceable surface area and electrical resistance.

Would you like to to study energy transport / heat flux in detail? Hukseflux helps taking your measurement to the next level: order FHF04 with radiation-absorbing black and radiation-reflecting gold stickers. You can then measure convective + radiative flux with one, and convective flux only with the other. Subtract the 2 measurements and you have radiative flux. BLK – GLD stickers can be applied by the user to the sensor. Optionally, they can be ordered pre-applied. See the BLK – GLD sticker series user manual and installation video for instructions.

Features

flexible (bending radius ≥ 15 x 10?3 m)

low thermal resistance

wide temperature range

fast response time

integrated type T thermocouple

robustness, including metal connection block, may be used as strain relief

IP protection class: IP67 (essential for outdoor application)

integrated thermal spreaders for low thermal conductivity dependence

Specifications

Measurand heat fluxtemperature
Measurement range (-10 至 +10) x 103 W/m2
Sensitivity (nominal) 11 x 10?? V/(W/m2)
Temperature sensor type T thermocouple*
Thermal spreaders included
On-line functionality testing self-test including self-calibration
Rated bending radius ≥ 15 x 10?3 m
Rated load cable ≤ 1.6 kg
Outer dimensions foil with guard (50 x 50) x 10?3 m
Sensing area 9 x 10?? m2
Sensor thermal resistance 23 x 10?? K/(W/m2)
Sensor resistance range 160 至 240 Ω
Sensor thickness 0.7 x 10?3 m
Uncertainty of calibration ± 5 % (k = 2)
Rated temperature range - continuous use -40 to +120 oC
IP protection class IP67
Standard wire length 2 m
Heater resistance 100 Ω
Heater power supply 12 VDC
Options with 5 m wire length; BLK-5050 black sticker; GLD-5050 gold sticker
* temperature measurement uncertainty: 2 % of value in C. For details, refer to user manual.
** rated operating conditions: 120 ?C continuous use, 150 ?C short intervals; use to -80 ?C is possible.
*** sensor is not suitable for continuous exposure to water.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 欧美午夜伦理电影 | 九九免费久久这里有精品23 | 国产精品久久久久久久久免费桃花 | 色爱区综合激月婷婷激情五月 | 亚洲国产精品一区 | 99久久精品国产一区二区三区 | 日本人视频18jizz免费 | 欧美91在线| 亚洲国产视频一区二区 | 一级毛片直接看 | 久久久亚洲欧美综合 | 欧美精品色婷婷五月综合 | 99在线视频精品费观看视 | 一级黄色毛片 | 午夜色大片在线观看 | 青娱乐极品视觉盛宴在线 | 国产在线观看精品 | 亚洲三级在线看 | 久久婷婷五月国产色综合 | 国产真实乱16部种子 | 欧美日韩综合视频 | 97久久精品 | 亚洲巨乳自拍在线视频 | 一级片一级片一级片 | 欧美在线视频观看免费视频 | 亚欧在线观看 | 欧美日一区二区 | 一级毛片免费 | 青青青青啪视频在线观看 | 寄生虫系列之钻阴虫3动画片 | 一级一片免费视频 | 亚洲综合色婷婷六月丁香 | 亚洲精品一级 | 成人免费va视频 | 国产精品久久久久永久免费观看 | 91在线网站 | 久久不雅视频 | 99re在线播放 | 国产精品一区在线 | 亚洲免费观看视频 | аⅴ资源新版在线天堂 |