5TE Soil moisture, Temperature and Conductivity Sensors

Updated:2025-03-13

Views:553

  • Brand: METER
  • Model: 5TE
  • Description: The 5TE sensor determines soil moisture content, conductivity, and temperature at an oscillating frequency of 70MHz. The water content is determined by measuring the dielectric constant of the soil. T
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

5TE Soil moisture, Temperature and Conductivity Sensors Description:

User's Manual

The 5TE sensor determines soil moisture content, conductivity, and temperature at an oscillating frequency of 70MHz. The water content is determined by measuring the dielectric constant of the soil. The thermistor at the base of the triforked probe measures the soil temperature, and the conductivity is measured by screws in the middle of the surface of two of the probes. Background In 2006, Decagon developed 5TE by combining EC-5 and ECH2O-TE. Using the same theoretical basis as ECH2O-TE, 5TE can also measure soil moisture content, conductivity and temperature at the same time. The difference is that the 5TE uses stainless steel screws to determine the conductivity, while the ECH2O-TE uses gold-plated wire. In contrast, the 5TE is designed to be more robust and corrosion-resistant. In addition, 5TE uses a 5-point calibration of the dielectric constant, which is more accurate than the ECH2O-TE.

Measurement Theory

Volume moisture content 5TE The permittivity of the surrounding medium is determined by the principle of electromagnetic field. The sensor provides an oscillating electromagnetic wave of 70MHz, which charges the sensor according to the dielectric constant of the medium. The stored electricity is proportional to the dielectric constant and volumetric water content of the soil. The 5TE microprocessor measures the amount of charge and outputs the dielectric constant value. Temperature 5TE uses a thermistor mounted on the surface to measure temperature. It is located under the black plastic housing at the base of the forked probe, near one of the probes, and measures the temperature of the probe surface. 5TE normally outputs in °C, unless otherwise specified in the preferences file in the ECH2O DataTrac or ECH2O Utility program. It should be noted that if the black plastic housing at the base of the probe is in direct sunlight, the temperature reading will be very high. At the same time, direct sunlight can also seriously affect the service life of the sensor. It is recommended not to expose the plastic housing part to sunlight when installing the sensor.

EC

Electrical conductivity (EC) is an index used to characterize the ability of a substance to conduct current, and can be used to infer the content of polar molecules in a solution. The conductivity is determined by applying a changing current to the two electrodes to determine the impedance between the electrodes. The conductivity is equal to the reciprocal of the impedance multiplied by the unit constant (distance between electrodes/electrode area). 5TE determines EC using a dual probe array located on the stainless steel screws of two of the forked probes. The trace oil on the skin will greatly affect the accuracy of EC determination after contact with the screw. If this happens, please refer to the cleaning section at the end of the manual to clean the screws. 5TE measures the volume conductivity of the surrounding medium (bulk EC). The calibration values of bulk EC at the factory guarantee an accuracy of ±10% in the conductivity range of 0 to 7dS/m. This accuracy range fully meets most field, greenhouse and nursery measurements. However, the conductivity of soil with high salt content will be higher than the above calibration range. The measurement range of 5TE can be up to 23.1 dS/m bulk EC, when the bulk EC is higher than 7 dS/m, the user needs to calibrate. In addition, EC measurements above 7 dS/m are very sensitive to grease on the electrode surface. If you are measuring saline soil, be sure to read the sensor cleaning section at the end of the manual.

Data Acquisition Communication

When the excitation voltage is turned on, the 5TE is measured. Within the excitation time of 50ms, the 3 parameters were input in ASCII code. 1200 baud rate 8-bit asynchronous continuous output, none parity, one stop bit. Voltage range is 0-3.6V, transistor logic circuit. Power off during test interval. Three parameters are separated by Spaces in an ASCII data string. The data string ends with a carriage return. The first value is the original permittivity, the second is the original conductivity value, and the third is the original temperature value. The following shows how raw values are converted to standard unit values.

5TE Soil moisture, Temperature and Conductivity Sensors Specification:

Indicator Accracy Apparent permittivity (εa) : ±1εa (none units) from 1-40 (soil range), ± 15% from 40-80
Soil volumetric Water Content (VWC) : using the Topp equation: solution conductivity < Typical ±0.03 m3 / m3 (± 3% VWC) in 10 dS/m mineral soils using medium specific calibration, ± 0.01-0.02 m3 / m3 (± 1-2% VWC) in any porous medium
Electrical conductivity (EC) : ± 10% from 0 to 7 dS/m, user calibrated above 7 dS/m
Temperature: ±1°C
Precision specification εa: 0.1εa is 1-20, < 0.75εa is 20-80
VWC:0.0008m 3 / m 3(0.08%VWC),0 ~ 50%VWC
EC: 0.01dS/m, from 0 to 7dS/m, 0.05dS/m, from 7 to 23.1dS/m
Temperature: 0.1℃
Measuring range εa: 1 (air) ~ 80 (water)
EC: 0-23dS/m (body)
Temperature: -40-60 °C
Measured Time 150 ms
Sensor type VWC: frequency domain
EC: Two probe design
Temperature: Thermistor
Output RS232(TTL),SDI-12 ,RS485
Operating Environment -40° to 60 ° C
Power Supply 3.6-15 VDC, 0.3 mA static, 10 mA during 150 ms measurement
Cable Length The sensor comes standard with 5 meters of cable. Custom cable lengths are available. The maximum cable length is 75 m.
Cable connector type 3.5mm "stereo" plug, or strip tinned wire (3)
Sensor Sizes 10cm×3.2cm×0.7cm
Data Logger Em50,ProCheck,Campbell Scientific, SDI-12 Converter

Note: This product can be customized according to customer requirements interface (RS232/RS485), communication protocol (MODBUS), etc. In addition, the company has RS232/RS485 to SDI-12 module, which is convenient for customers to secondary development and debugging. Please click if necessarySDI-12 Converter to RS232 RS485

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 欧美天天综合 | 精品乱码一区二区三区四区 | 日韩se| 亚洲午夜精品专区国产 | 亚洲美女在线视频 | 亚洲精品成人久久久 | www.久色 | 久久国产精品一区二区三区 | 黄色免费视频在线观看 | 9色网站 | 毛片在线网站 | 久草热在线 | 久久99精品久久久久久首页 | 国产日韩欧美视频 | 日韩欧美一区二区三区免费观看 | 亚洲高清一区二区三区 | 久久无码精品一区二区三区 | 亚洲精品免费日日日夜夜夜夜 | 羞羞网站视频 | 日本韩国在线视频 | 亚洲成av人影片在线观看 | 色偷偷免费视频 | 国产有色视频 | 三区在线 | 九九热网 | 天天干天天色综合网 | 久久人妻无码毛片A片麻豆潘金莲 | 精品亚洲一区二区三区 | 日韩不卡在线播放 | 99精品在线 | 久热中文字幕在线精品免费 | 日韩精品一区二区三区视频播放 | 久久久久久看片 | 四虎国产精品免费五月天 | 久色免费 | 久久精品无码一区二区三区 | 一区二区三区免费电影 | 久久成人精品视频 | 日韩不卡一区二区三区 | 色婷婷综合久久久久中文 | 亚洲免费在线视频观看 |