LEAK CURRENT HiTESTER ST5540 Description:

Orientation Pack Brochure

To ensure the safe use of electrical products, electrical safety tests such as insulation resistance, withstand voltage, ground resistance, and leakage current must always be conducted. Hioki Leakage Current Testers comply with laws and standards regarding medical electrical equipment as well as non-medical electrical equipment, and can be used to measure leakage current in all types of electrical products from computers to medical equipment.

The ST5540 consists of measurement networks that simulate the human body and a high-frequency volt meter, and is also capable of switching power supply polarities and making measurements under simulated single fault conditions in equipment under test.

Leak Current Measurement - Essential to Electrical Safety

The ST5540 series features an improved measuring method and dramatically faster cycle times thanks to its uninterrupted polarity switching capability. The new devices support rated currents of up to 20A, making it more than ideal for use with products built to new standards.

Leak Current Testing of Medical Electrical Devices

In order to prevent the danger of electric shock, electrical devices use power supplies that are isolated from parts of the device that may come into contact with the body. However, it is impossible to achieve infinite insulation resistance. Some leak current always exists, and its magnitude changes as the insulation degrades over time. The LEAK CURRENT HiTESTER ST5540/ST5541 provides an easy-to-operate solution for measuring leak current in electrical devices, making it eminently suitable for use in an extensive array of applications, ranging from production lines to equipment maintenance and inspections.

Key Features

Compliance with IEC 60601-1:2005 Ed 3.0, JIS T 0601-1:2012 for medical-use electrical devices and essential to electrical safety (*1)

Compliance with Electrical Appliances and Materials Safety Act, JIS, IEC, and UL standards for general-use electrical devices

Uninterrupted polarity switching function dramatically reduces cycle time

Support for rated currents up to 20 A gives the instrument more than adequate capability for testing products designed to comply with new standards

Communications functionality and external I/O support allow automatic testing on production lines

Basic specifications

Measurement methods Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground.
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
Standards compliance
(NW: Body simulated resistance)
[NW-A] ? Electrical Appliances and Materials Safety Act
[NW-B1] ? Medical electrical equipment: IEC 60601-1:1988+ A1:1993+ A2:1995, JIS T 0601-1:1999
[NW-B2] ? Medical electrical equipment: IEC 60601-1:2005+ A1:2012, JIS T 0601-1:2012 and complement 1:2014, IEC 62353
[NW-C]
? Measurement of touch current and protective conductor current: IEC 60990:2016
? Electrical equipment for measurement, control, and laboratory use: IEC 61010-1:2010+ A1:2016
? Information technology equipment: IEC60950-1:2005+ A1:2009+ A2:2013
? Audio, video and similar electronic apparatus: IEC 60065:2014
? Personnel Protection Systems for EV: UL 2231-1:2012 (Amended 2016), UL-2231-2:2012 (Amended 2016)
[NW-D] ? For UL: UL 1492:1996 (Amended 2013)
[NW-G] ? Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1:2010+ A1:2016
Leak current measurement Ground leak current, 3 types of contact current, 7 types of patient leak current, patient measurement current, 4 types of total patient leak current, free current measurement, 3 types of enclosure leak current
Measurement current DC, AC (true rms, 0.1 Hz to 1 MHz), AC+DC (true rms, 0.1 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
Measurement ranges DC / AC / AC+DC mode: 50.00 mA/ 5.000 mA/ 500.0 μA/ 50.00 μA
AC peak mode: 75.0 mA/ 10.00 mA/ 1.000 mA/ 500.0 μA
Measurement accuracy
(current measurement)
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
Interfaces External I/O, medical device relay output, USB 1.1 (communications), RS-232C
Functionality 110% voltage application, automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
Power supply 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Target device power supply input 100 to 250 V AC, 50/60 Hz Rated current input from terminal block: 20 A
Target device power supply output Output from terminal block: 20 A Output from outlet: 15 A
Dimensions and mass 320 mm (12.60 in)W × 110 mm (4.33 in)H × 253 mm (9.96 in)D, 4.5 kg (158.7 oz)
Included accessories Test lead L2200 (for ST5540, Red ×2, Black ×1) ×1 set, Enclosure probe 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, CD-ROM ×1

ST5540, ST5541 List of functions (Network)

Item ST5540 ST5541
Network A
(Electrical Appliances and Materials Safety Act)
Network B (Medical-use electrical devices) -
Network C (IEC 60990)
Network D (UL)
Network E (General-purpose 1)
Network F (General-purpose 2)
Network G (IEC 61010-1)

List of functions (Major functions)

Item ST5540 ST5541
Power on polarity switching function
Rated current 20 A
Function for checking for blown fuses
Frequency band switching -
110% voltage output terminal (T3 terminal) -
S10, S12, S13, E terminal -

List of functions (Testing leakage current mode)

Item ST5540 ST5541
Earth leakage current
Touch current
Patient auxiliary current -
Patient leakage current -
Total patient leakage current -
Free current
Enclosure - Earth leakage current
Enclosure - Enclosure leakage current
Enclosure - Line leakage current
Patient leakage current I -
Patient leakage current II -
Patient leakage current III -

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: www国产在线观看 | 99久久99这里只有免费费精品 | 久久国产亚洲精品 | 欧美一级在线 | 亚洲伊人99综合网 | 国产麻豆一级在线观看 | www.夜色 | 黄色网页在线观看 | 精品福利视频网站 | 午夜影视在线免费观看 | 国产成人高清亚洲一区久久 | 26uuu久久| 巨大乳女人做爰视频在线看 | 国产亚洲欧美日韩在线看片 | 国产疯狂露脸对白 | 特级黄一级播放 | 亚洲午夜日韩高清一区 | 久久久久久国产精品 | 97久久精品 | 成人国产精品久久 | 午夜电影网| 99久久精品国产综合一区 | 欧美激情视频一区二区三区在线播放 | 国产成人精品午夜视频' | 2021国产精品最新在线 | 91自啪| 国产精品久久一区 | 久久6| 国产成人精品第一区二区 | 久久精品国产精品青草 | av中文在线 | 欧美一区二区三区 | 久久亚洲综合中文字幕 | 男女无遮挡边做边吃视频免费 | 婷婷久久激情综合啪啪 | 久久蜜桃精品一区二区三区综合网 | 日韩中文欧美 | 日韩二区三区 | a毛片| 在线日韩中文字幕 | 日本黄色小视频网站 |