  • Model:SASS
  • Description: Met One’s Speciation Samplers are designed to comply with and exceed EPA Speciation requirements. Two models provide a choice for compliance monitoring: SASS, a 5 channel sampling system; and SUPER SA
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

SASS and SUPER SASS Speciation Sampler Introduction:

user's manual

Met One’s Speciation Samplers are designed to comply with and exceed EPA Speciation requirements. Two models provide a choice for compliance monitoring: SASS, a 5 channel sampling system; and SUPER SASS, an 8 channel, multiple event, sampling system. The SASS conforms to original EPA requirements and SUPER SASS adds benefits suggested by state and local authorities. Both models use concepts pioneered by Met One Instruments, such as the contamination free Canister, solar radiation shield, and modular design. SASS and SUPER SASS not only comply to EPA specifications, they exceed the specifications; as proven in EPA and California Air Resources Board field studies.

SASS FEATURES:

  • Portable integrated ambient particulate sampling system
  • Inlet for PM2.5 at 6.7 liter/minute sample rate
  • Solar shield maintains cassettes to less than <5°C over ambient temperature
  • Canister provides data integrity – contamination proof
  • New multi-cell denuder and multiple filter medias

SUPER SASS FEATURES:

This unit offers all the features of the SASS plus it has sequential programing to allow multiple day operation. SUPER SASS will sample up to eight days depending on the number of sample channels used per day. SUPER SASS comes standard with four independent volumetric flow controllers, one for each sampler group.

  • Up to 8 Channel Operation
  • One to Eight day Sampling, Sequential
  • Automatic Volumetric Flow Controllers
  • Automatic Volumetric Flow Controllers
  • Advanced Field Audit Screens
TESTING AND EXPERIENCE:

The SASS and SUPER SASS are based on designs that have been field tested for eight years with 3 years of testing in the EPA program. This testing has proven the concept and helped to refine the design.

PORTABILITY:

Designed for programs on the move, both units offer superior flexibility and portability. SASS and SUPER SASS are composed of a portable pump box, tripod, sample head and controller, they are easy to carry and easy to install. Installation takes less than one hour.

NO FIELD MAINTENANCE:

The SASS allows all critical maintenance to be performed in the lab. Other instruments suffer contamination of inlet, manifold and PM2.5 separator because they must be serviced in the field. With the integrated canister every element of the sampler that is contacted by the sampled air stream is cleaned with each sample change.

NO FIELD CONTAMINATION:

Sample Canisters are loaded in the lab with blank filter cassettes. Sealed canisters are shipped to speciation field sites for deployment. After exposure, the canisters are sealed for shipment to the lab. This approach circumvents contamination due to field handing of the sample.

TEMPERATURE CONTROL:

SASS incorporates a convective solar radiation shield to maintain the samples within 5°C of ambient temperature.

FIELD AND LAB TESTED PM 2.5 INLET:

A Sharp Cut Cyclone (SCC) with a flow of 6.7 liters/min is integrated in every sampling canister to remove particles larger than 2.5 μm aerodynamic diameter. Test report available upon request.

CANISTER CONFIGURATIONS:

The sample canister contains the SCC and all necessary components for excluding particles above 2.5 μm aerodynamic diameter, for removing interfering gases, and for collecting particles including semi-volatile. The sampling canisters are designed to accommodate denuders and one or two filters for sampling of semi-volatile species, and for collection of gases such as nitric acid, ammonia, and formic acid. For example, a Teflon Nylon filter pair can be operated behind a nitric acid denuder to include inorganic ions and nitrate in the same cassette. Canisters can be used as follows: (1) Teflon filter for mass and trace metals, (2) Teflon or Quartz for inorganic ions by ion chromatography, (3) Denuded Nylon or impregnated filter for nitrate, (4) Tandem Quartz for organic and elemental carbon, with backup filter for artifact collection, (5) Denuded carbon-impregnated filter for semi-volatile organic compounds.

APPLICATIONS:
  • Ambient Monitoring
  • Environmental Monitoring
  • Climate Research

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 国产精品免费av一区二区三区 | 97精品国产 | 成人激情视频网站 | 国产日本久久久久久久久婷婷 | 欧美在线观看禁18 | 国产成人精品一区二区三在线观看 | 色噜噜人体337p人体 | 人人干美女| 99久久99久久| 天天综合网天天综合色不卡 | 奇米在线| 成人18网址在线观看 | 天天爱天天做天天爽夜夜揉 | 久久亚洲综合 | 高清国产一区 | 国产成人激情 | 国产真人做爰免费视频 | 天天影视色香欲综合网 寡妇 | 99九九精品视频 | 欧美大bbbbbbbbb | 成人在线播放视频 | 狠狠爱www人成狠狠爱综合网 | 91视频综合 | 国产韩国精品一区二区三区 | 国产高清视频免费观看 | 亚洲狠狠 | 在线免费观看黄色网址 | 2017天天天天做夜夜夜做 | 狠狠色噜噜噜噜狠狠狠狠狠狠奇米 | 久久综合一区二区 | 先锋五月婷婷丁香草草 | 久久亚洲国产 | 黄色资源网 | 成人国产精品久久久免费 | 欧美激情久久久 | 国产精品国产三级国产专播下 | 微拍秒拍99福利精品小视频 | 日韩欧美精品一区二区三区 | 婷婷99 | 国产成人在线看 | 女人毛片a毛片久久人人 |