成人亚洲精品777777-成人亚洲精品久久久久-成人亚洲精品久久久久软件-成人亚洲区无码区在线点播-成人亚洲性情网站www在线观看-成人艳情一二三区

Products

current position:home page>Products>Measuring Instrument>Hukseflux>

NR01 4-component net radiometer

Updated:2025-03-13

Views:187

  • Brand: Hukseflux
  • Model:NR01
  • Description: NR01 is a market leading 4-component net radiometer, mostly used in scientific-grade energy balance and surface flux studies. It offers 4 separate measurements of global and reflected solar and downwe
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

NR01 4-component net radiometer: User's Manual Datasheet

NR01 Measures the 4 Separate Components of the Surface Radiation Balance

NR01 measures the 4 separate components of the surface radiation balance: downward and upward solar and longwave radiation. The solar radiation sensors are called pyranometers and the longwave sensors are called pyrgeometers. From these 4 separate components the net radiation is derived. For calculation of sky- and surface temperatures, it is necessary to compensate for irradiated heat by the pyrgeometers themselves (Stefan-Boltzmann law). A Pt100 temperature sensor is included in NR01’s body for that purpose. Sunshine duration may be estimated according to the WMO approved pyranometric method.

NR01 Operation

Using NR01 net radiometer is easy. It can be connected directly to commonly used data logging systems. The irradiance levels in W/m2 are calculated by dividing the NR01 outputs, small voltages, by the sensitivities. The longwave irradiance should be corrected using the instrument body temperature. The sensitivities of all sensors are provided with NR01 on its product certificate.

NR01 Benefits

In order to prevent condensation of water on the pyrgeometer windows, NR01 has internal heating close to the pyrgeometers. This keeps the instrument above dew point. As water blocks longwave radiation, heating will improve the reliability of longwave radiation measurement, in particular at night, when the risk of condensation is highest. Solar offsets in the longwave radiation measurement are very low. NR01 net radiometer has a modular design with 2 pairs of identical sensors: it is possible to take the instrument apart and easily replace individual sensors, and recalibrate them in using the same procedure. Features like these have made NR01 net radiometers popular in energy balance and surface flux studies. In addition, NR01 is practical to mount; it is much lighter than competing models and a 2-axis levelling assembly is included. The levelling assembly fits a 1 inch NPS tube (the tube’s recommended outer diameter equals 33.4 x 10?3 m). With the NR01 shim, included in NR01’s delivery, a ? inch NPS tube may also be used.

Suggested Use

  • energy balance studies
  • surface flux measurements
  • climatological networks
  • Areas of Application

  • Building physics / insulation, thermal comfort and energy budget measurement
  • Meteorology / surface energy flux measurement
  • NR01 4-component net radiometer Specifications:

    Measurands Downward longwave radiation*, global solar radiation, net radiation, reflected solar radiation, upward longwave radiation*
    Optional measurands Albedo or solar reflectance, sky temperature*, solar duration, surface temperature*
    Included sensors 2 x identical ISO 9060 second class pyranometers 2 x identical pyrgeometer with 150° field of view angle
    Spectral range solar 285 to 3000 x 10?? m
    Calibration traceability solar to WRR
    Calibration uncertainty solar < 1.8 %
    Spectral range longwave 4.5 to 40 x 10?? m
    Calibration traceability longwave to WISG
    Calibration uncertainty longwave < 7 %
    Temperature sensor Pt100
    Heater on pyrgeometer 1.5 W at 12 VDC
    Rated operating temperature range -40 to 80°C
    Required readout 4 x DC voltage,
    Levelling 2-axis levelling assembly (included)
    Mounting ? inch NPS tube (not included)
    Standard cable length 2 x 5 m (see options)
    * Required measurand instrument body temperature
    Options ? Longer cable, in multiples of 5 m, cable lengths above 20 m in multiples of 10 m
    ? 10 k? thermistor instead of Pt100 temperature sensor

    WeChat

    Customer Service QQ

    Customer Hotline:

    010-52867770
    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    0l0-52867774
    l7896OO5796
    info@dorgean.com
    主站蜘蛛池模板: 日韩精品一区二区三区视频播放 | 欧美三区在线观看 | 中国妞xxxhd露脸偷拍视频 | 中国一级毛片在线播放 | 91短视频网址 | av中文字幕在线播放 | 国产成人久久精品麻豆二区 | 久久伊人国产精品 | 国产精品亚洲欧美 | 高清欧美一区二区三区 | 毛片毛片 | 精品一区二区三区中文 | 香港aa三级久久三级 | 欧美精品专区免费观看 | 亚洲欧美v | 高清国产性色视频在线 | 久久中文网 | 国产精品伦一区二区三级视频 | 精品欧美一区二区三区久久久 | 国产精品一区二区三区四区 | 日本精品在线观看 | 精品亚洲一区二区三区四区五区 | 全部毛片免费看 | 国产欧美一区二区精品性色 | 天无日天天射天天视 | 亚洲欧美一区二区三区久久 | 竹内纱里奈55在线观看 | 天天色天天色 | 久草在线免费资源 | 三级大黄 | 久热中文在线 | 欧美国产亚洲精品高清不卡 | jizzjizzjizz美国 | 午夜精品一区 | 久草电影在线 | 国产精品久久久久久久久久免费 | 欧美大片日韩精品四虎影视 | 天天综合网网欲色 | 免费一区二区三区 | 亚洲大片免费 | 色综合天天综合网亚洲影院 |