成人亚洲精品777777-成人亚洲精品久久久久-成人亚洲精品久久久久软件-成人亚洲区无码区在线点播-成人亚洲性情网站www在线观看-成人艳情一二三区

Products

current position:home page>Products>Analysis Instrument>PST>

AII Portable Oxygen Analyzers GPR-1000/1100/2000/3500 MO

Updated:2025-03-13

Views:181

  • Brand: PST/AII
  • Model: GPR-1000/1100/2000/3500 MO
  • Description: Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxy
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

AII Portable Oxygen Analyzers GPR-1000/1100/2000/3500 MO Description:

GPR-1100 User's Manual GPR-1000 User's Manual GPR-2000 User's Manual GPR-3500 MO User's Manual Datasheet

For Field Spot Checks from PPM to 100% Oxygen

Features

Measurement ranges from 0-10 ppm up to 0-100% O2

Up to 5 ranges per model with manual or auto-ranging feature

ATEX models are rated for IIC gases

Rugged design, proven to last in field operation

Lightweight (2.5Kgs) and easy to use

Up to 30 days battery life (40 hours with pump)

24 to 32 months sensor life span (in normal use)

Internal pump option

0-1V output

XLT sensor options for CO2?background

Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in their reliability and accuracy.

The Analytical Instruments concept of using the same HMI and menu structures for portable and online analyzers makes it extremely easy for operators to use both types of instruments on their site without need for extra training.

Specifications

GPR-1100 GPR-1000 GPR-2000 GPR-3500 MO
Measurement range 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% 0-1000 ppm, 0-1%, 0-25% 0-1%, 0-5%, 0-10%, 0-25% 0-100%
Accuracy < 2% of selected range at constant conditions < 2% of selected range at constant conditions < 2% of selected range at constant conditions < 2% of selected range at constant conditions
Response time T90 < 10 seconds T90 < 10 seconds T90 < 10 seconds T90 < 13 seconds
Recovery time 60 sec in air to < 10 ppm in < 1 hour on N2 purge 60 sec in air to < 100 ppm in < 15 min on N2 purge N/A N/A
Sensitivity (LDL) 0.05 ppm 5 ppm 0.01% 0.10%
Linearity < 1% of scale < 1% of scale < 1% of scale < 1% of scale
Sensor model GPR-12-333

XLT-12-333 for gas mixture with > 0.5% CO2
GPR-12-100-M

XLT-12-100-M for gas mixture with > 0.5% CO2
GPR-11-32-RTS

XLT-11-24-RTS for gas mixture with > 0.5% CO2
GPR-11-120-RTS
Sensor life at 25oC (77°F) and 1 atm 24 months in < 1000 ppm O2 GPR-11-32-RTS 32 months in air
XLT-11-24-RTS 24 months in air
GPR-11-32-RTS 32 months in air
XLT-11-24-RTS 24 months in air
24 months in 100% O2
Calibration interval 30 days 30 days 30 days 30 days
Inlet pressure 0.34 - 2 barg (5-30 psig) with atmospheric vent 0.34 - 2 barg (5-30 psig) with atmospheric vent 0.34 - 2 barg (5-30 psig) with atmospheric vent 0.34 - 2 barg (5-30 psig) with atmospheric vent
Flow rate 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH)
Gas connections 1/8" NPT male quick connect 1/8" NPT quick connect 1/8" compression tube fittings 1/4" compression tube fittings
Wetted parts Stainless steel Brass connections; stainless steel optional GP version: Brass, plastic
ATEX version: Stainless steel flow housing, tubing and fittings
Stainless steel
Display Graphical LCD 7 x 3.5cm (2.75 x 1.375") Graphical LCD 7 x 3.5cm (2.75 x 1.375") Graphical LCD 7 x 3.5cm (2.75 x 1.375") Graphical LCD 7 x 3.5cm (2.75 x 1.375")
Resolution 0.01ppm 1ppm 0.00% 0.10%
Enclosure Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Compensation Barometric pressure and temperature Barometric pressure and temperature Barometric pressure and temperature Barometric pressure and temperature
Signal output 0-1V 0-1V 0-1V 0-1V
LED indicators LOW BATT (72 hr. warning); CHARGE mode LOW BATT (72 hr. warning); CHARGE mode LOW BATT (72 hr. warning); CHARGE mode LOW BATT (72 hr. warning); CHARGE mode
Operating temperature 5°C to 45°C (41°F to 113°F) (GPR sensor),
-10° to 45°C (14°F to 113°F) (XLT sensor)
5°C to 45°C (41°F to 113°F) (GPR sensor),
-10° to 45°C (14°F to 113°F) (XLT sensor)
5°C to 45°C (41°F to 113°F) (GPR sensor),
-10° to 45°C (14°F to 113°F) (XLT sensor)
5°C to 45°C (41°F to 113°F)
Power Rechargeable battery (lead acid) Rechargeable battery (lead acid) Rechargeable battery (lead acid) Rechargeable battery (lead acid)
Battery life Up to 30 days on a single charge (40 hours with pump running) Up to 30 days on a single charge (40 hours with pump running) Up to 30 days on a single charge (40 hours with pump running) Up to 30 days on a single charge
Area classification ATEX: Ex II 2 G
Ex ib IIC T4 Gb
Tamb: 5°C to +45°C
ATEX: Ex II 2 G
Ex ib IIC T4 Gb
Tamb: 5°C to +45°C
ATEX: Ex II 2 G
Ex ib IIC T4 Gb
Tamb: 5°C to +45°C
General purpose only

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 亚洲精品日韩在线 | 超碰在线看 | 久久久久avav久久久 | 亚洲福利视频精选在线视频 | 欧美大片一级毛片 | 日本道精品一区二区三区 | 国产破处在线视频 | 国产这里只有精品 | 九九九好热在线 | 99久久久无码国产精品 | 国产成人77亚洲精品www | 国产精品视频网址 | 欧美日韩在线成人 | 久久成人免费播放网站 | 欧美天堂视频 | 91福利国产在线观一区二区 | 五月天影院,久久综合, | 久久综合久久伊人 | 日韩精品一区二区三区免费视频 | 国产精品久久久视频 | 伊人久热这里只有精品视频99 | 欧美精品一区二区三区四区 | 久草在线网站 | www.操.com | 毛片网战 | 亚洲视频在线观 | 成人免费观看av | 99免费在线视频 | 国产亚洲精品自在久久77 | 亚洲精品天堂一区二区三区 | 国产精品久久久久久久毛片 | 91免费观看国产 | 久草日韩 | a毛片免费看 | 99久久er热在这里都是精品99 | 亚洲美女网站 | 四虎在线视频 | 欧美日韩免费在线 | 国产999精品久久久影片官网 | 日韩欧美理论 | 干干天天 |