成人亚洲精品777777-成人亚洲精品久久久久-成人亚洲精品久久久久软件-成人亚洲区无码区在线点播-成人亚洲性情网站www在线观看-成人艳情一二三区

Products

current position:home page>Products>Analysis Instrument>PST>

Explosion Proof Moisture Transmitter - Easidew PRO XP

Updated:2025-03-13

Views:135

  • Brand: Ophir
  • Model: Easidew PRO XP
  • Description: The Easidew PRO XP moisture transmitter is an explosion-proof dew-point transmitter for trace moisture measurements in gases or liquids in hazardous areas. It is certified by ATEX, UKCA, cQPSus, IECEx
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Explosion Proof Moisture Transmitter - Easidew PRO XP Description:

Product Manual

Reliable Analysis of Dew-Point or Moisture Content in Gases and Liquids

Features

Measurement ranges -110 up to +20 °Cdp (-166 to 68 °Fdp)

Global explosion / flameproof certification

Accuracy ±1 °Cdp (±1.8 °Fdp)

2-wire 4...20 mA output

Traceable 13-point calibration certificate

450 bar (6527 psi) pressure rating

Low cost of ownership and easy maintenance with sensor exchange program

3/4” UNF industry standard process connection

EN 10204 3.1 material certification

Moisture in gases and liquids

Integral display meter

Oxygen service cleaned

The Easidew PRO XP moisture transmitter is an explosion-proof dew-point transmitter for trace moisture measurements in gases or liquids in hazardous areas. It is certified by ATEX, UKCA, cQPSus, IECEx, and GOST for use in any North American, European or Asian zone.

The transmitter has a wide dew-point measurement range of –110 to +20 °Cdp (-166 to 68 °Fdp) with industry-standard process and electrical connections, ensuring low installation costs. The Easidew PRO XP incorporates the latest Michell Ceramic Metal-Oxide Moisture Sensor providing stable and reliable measurements for all new and replacement moisture applications. The unit can also be supplied with an integral 4-digit LED display, displaying the configured moisture output signal.

Specifications

Easidew PRO XP for Gases Easidew PRO XP LQ for Liquids
Performance Specifications
Measurement Range -110...+20 °C (-166...+68 °F) dew point;
-100...+20 °C (-148...+68 °F) dew point
0...1000 ppmW capability – factory configured to customer-required range and application
Accuracy ±1 °C (±1.8 °F) dew point (+20...-60 °C / +68...-76 °F);
±2°C (±3.6 °F) dew point (-60...-110°C / -76...-166 °F)
Response Time 5 mins to T95 (dry to wet)
Repeatability 0.5 °C (32.9 °F) dew point
Calibration Traceable 13-point calibration and certificate
Electrical Specifications
Output Signal 4...20 mA (2-wire connection, current source); User configurable over range
Output Dew point or moisture content Moisture content
Analog Output Scaled Range Dew point: -110...+20 °C (-166...+68 °F)
Moisture content in gas: 0...3000 ppmV
Non-standard:mg/m3, lbs/MMSCF natural gas
Moisture content in liquid: 0...1000 ppmW capability – factory configured to customer-required range and application
Supply Voltage 14...28 V DC
Load Resistance Max 250 Ω @ 14 V (500 Ω @ 24 V)
Current Consumption 23 mA max, depending on output signal
Saturation Constants
(for moisture in liquids measurements only)
6-point look-up table for saturation constants up to 1000 ppmW over the temperature range 0...+50 °C (+32...+122 °F); saturation constants for 8 common liquids can be programmed into the Easidew PRO XP LQ via the application software;
Alternatively the user can program saturation constants manually
Compliances CE & UKCA
Operating Specifications
Operating Temperature -40...+60 °C (-40...140 °F)
Compensated Temperature Range -20...+50 °C (-4...+122 °F)
NOTE: The transmitter accuracy statement is only valid for the temperature range: -20/+50 °C (-4/+122 °F)
Storage Temperature -40...+60 °C (-40...+140 °F)
Operating Pressure 45 MPa (450 barg/6527 psig) maximum
Flow Rate 1...5 Nl/min mounted in standard sampling block
0...10 m/sec direct insertion
0.1...0.3 L/min through Easidew sample block
0.1...1 m/s direct insertion
Mechanical Specifications
Ingress Protection IP66 in accordance with standard BS EN 60529:1992;
NEMA 4 protection in accordance with standard NEMA 250-2003
Explosion and Flameproof Area Certificates*
Standard: aluminium Optional: 316 stainless Steel
ATEX/UKCA: II 2 GD Ex db ia IIC T6 Gb
EX tb IIIC T80°C Db IP66
Tamb -20 °C...+70 °C

II 2 GD Ex db ia IIC T6 Gb
EX tb IIIC T80 °C Db IP66
Tamb -20 °C...+70 °C

IECEx: Ex db ia IIC T6 Gb
Ex tb IIIC T80 °C Db IP66
Tamb -20 °C...+70 °C

Ex db ia IIC T6 Gb
Ex tb IIIC T80 °C Db IP66
Tamb -20 °C...+70 °C

cQPSus: Class I, Division 1, Groups ABCD T6
Class II & III, Division 1, Groups EFG
Class I, Zone 1 AEx/Ex db ia
IIC T6 Gb
Class I Zone 21, AEx/Ex tb IIIC
T80 °C Db

Class I, Division 1, Groups ABCD T6
Class II & III, Division 1, Groups EFG
Tamb -20 °C...+70 °C

Pattern Approval Kazakhstan (GOST-K)
Additional Approvals TRCU 012 (EAC), Japan Ex, PESO (India), NEPSI (China), KCS (Korea)
Canadian Pressure Vessel Certification C.R.N. - all Canadian provinces
Oxygen service Optional: cleaned for enriched oxygen
Housing material Standard: Aluminium (copper free), epoxy and polyurethane powder coated, blue RAL 5009
Optional: 316 stainless steel (supplied with BS EN 10204 3.1 material certificate if option F2 requested)
Filter (sensor protection) Standard: Stainless steel sintered guard (for protection against fine particulate >80μm)
Optional: HDPE guard (for protection against fine particulate >10μm)
Process Connection and Material 3/4” - 16 UNF with recessed Viton® O-ring
316 stainless steel: Optional O-ring: Kalrez **
Weight Aluminium: 1.6kg (3lb 8oz)
316 Stainless Steel: 2.4kg (5lb 5oz)
Electrical Connections Dual 3/4” NPT gland
Programmable display meter range Optional: -1999...+9999
Programmable display decimal point Optional: 0...3 decimal places
Display meter overload limits Optional: 3.6 mA & 20.4 mA
Programmable display meter scales Optional: °C, °F, %, No Scale
Stainless Steel Tags Optional: 316 stainless steel tags (70 x 25mm / 2.76 x 1in)
Diagnostic conditions (factory programmed) Conditions: Sensor fault, Under-range dew point,
Over-range dew point
Output: 23 mA, 4 mA, 20 mA
* The end user has a responsibility to ensure that when installed in the Hazardous Area, the system is compliant with relevant local and international installation Standards for the use of equipment in explosive atmospheres.
** Kalrez O-ring is non standard and available at an additional cost detailed on the price list.

Suitable Applications

Moisture measurements in natural gas processing and transmission

Moisture in feedstock for polymer production

Biomethane gas production

Hydrogen coolants

LNG & LPG production

Inert & bulk gases

CNG production

Hydrocarbon refinery processing

Heat treating furnaces

Catalyst protection

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 精品一区二区久久久久久久网精 | 浮力影院5826最新地址 | 香港国产特级一级毛片 | jizz黑丝 | 精品一区二区三区91 | 亚洲欧美日韩一级特黄在线 | 91网站在线播放 | 91在线免费看 | 成人国产午夜在线视频 | 亚洲精品国产精品一区二区 | 五月天综合激情 | 这里只有精品在线 | 亚洲毛片在线观看 | 色婷婷综合久色aⅴ | 91久色| 国产欧美一区二区三区在线看 | 嫩草影院在线播放www免费观看 | 在线观看91 | 亚洲国产精品久久久久秋霞不卡 | 日本欧美韩国一区二区三区 | 在线播放国产一区二区三区 | 国产精品99久久久久久www | 伊人网站| 先锋久久 | 91视频完整版高清 | 色综合合久久天天给综看 | 亚洲码欧美码一区二区三区 | 一级片在线观看 | 亚色视频在线观看 | 成人网18免费网 | 97天天做天天爱夜夜爽 | 婷婷亚洲综合小说图片 | 日韩丰满少妇无吗视频激情内射 | a级在线观看视频 | 日本一本在线 | 特级淫片日本高清视频免费 | 国产片在线观看 | 国产精品美女久久久久久免费 | 久久久久久久久久久福利观看 | 亚洲精品久久久久综合91 | 亚洲精品理论 |